Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting.Follow the heating equipment
manufacturer’s guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE
FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This
could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This blower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will
restart when it cools down.If the motor continues to shut off
and restart, have the hood serviced.
4. Please read specification label on product for further informa-
tion and requirements.
5. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside – Do not exhaust air
into spaces within walls or ceiling or into attics, crawl spaces,
or garage.
!
INSTALLER:
Save this manual for Electrical Inspector
and Homeowner to use.
INTERNAL BLOWER
(for use with RM60000 Series Range Hoods)
NOTE: This blower is compatible with older “60000
Series” Rangemaster
®
Hoods. Refer to the instal-
lation instructions included with the hood, visit
www.broan.com, or contact Technical Support.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - INTERNAL BLOWER

MODEL RM325HPage 1WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSON(S) OBSERVE THE FOLLOWING:1. Use this unit only in the manne

Page 2 - RANGE HOOD SYSTEM

MODÈLE RM325HPage 10PIÈCES DE RECHANGEVENTILATEUR REPÈRE N° DESCRIPTION QTÉ DE PIÈCE 1 99111448 BOÎTIER DE VENTILATEUR, MOTEUR 1 2 99

Page 3 - INSTALLATION

MODELO RM325HPágina 11ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO SIGUIENTE: 1. Use la unidad

Page 4 - MODEL RM325H

MODELO RM325HPágina 12SISTEMA DE CAMPANA DE ESTUFA CONVENTILADOR INTERNOTapas de pared y techo, ventiladores exterioresCodosSistema de tuberíaSiste

Page 5 - SERVICE PARTS

MODELO RM325HPágina 13INSTALACIÓN1. Fije el ventilador a la placa de montaje con cuatro (4)tuercas hexagonales 10-24 (incluido). 2. Tienda el cable

Page 6 - VENTILATEUR INTERNE

MODELO RM325HPágina 144. Quite la cubierta de la conexión eléctrica. 5. Conecte el cable eléctrico a la caja del cableado con el conector adecuado.

Page 7 - À VENTILATEUR INTERNE

MODELO RM325HPágina 15PIEZAS DE SERVICIOVENTILADOR CLAVE NÚMERO DESCRIPCIÓN CANT.N.º DE PIEZA1 99111448 CAJA DEL VENTILADOR, MOTOR 12 9911

Page 8

MODEL / MODÈLE / MODELO RM325HPage / Página 1699044969AWARRANTY / GARANTIE / GARANTÍABROAN-NUTONE ONE YEAR LIMITED WARRANTYBroan-NuTone warrants to

Page 9 - MODÈLE RM325H

MODEL RM325HPage 2INTERNAL BLOWERRANGE HOOD SYSTEMRoof &Wall CapsElbowDuctworkBlowerSystemDamperRM60000SERIES HOOD(Canopy withblower controls&

Page 10 - PIÈCES DE RECHANGE

MODEL RM325HPage 3INSTALLATION1. Attach blower to mounting plate with (4) 10-24 Hex Nuts (included).2. Run power cable to installation location, rem

Page 11 - VENTILADOR INTERIOR

MODEL RM325HPage 44. Remove wiring cover. 5. Connect power cable to wiring box using proper connector. Connect Black to Black (hot), White to White

Page 12 - CONVENTILADOR INTERNO

MODEL RM325HPage 5BLOWER KEY PART DESCRIPTION QTY NO. NUMBER 1 99111448 BLOWER HOUSING, MOTOR 1 2 99111447 BLOWER HOUSING, INLET 1

Page 13 - INSTALACIÓN

MODÈLE RM325HPage 6!AVERTISSEMENTAFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES, SUIVEZ CES DIRECTIVES : 1. N’utilisez cet

Page 14 - MODELO RM325H

MODÈLE RM325HPage 7SYSTÈME DE HOTTE À VENTILATEUR INTERNECapuchon mural et de toit, ventilateurs extérieursCoudesConduitSystème de ventilateurClapet

Page 15 - PIEZAS DE SERVICIO

MODÈLE RM325HPage 8INSTALLATION1. Fixez le ventilateur à la plaque de montage avec quatre (4)écrous hexagonaux 10-24 (inclus).2. Acheminez le câble

Page 16 - Page / Página 16

MODÈLE RM325HPage 94. Retirez le couvercle du boîtier de câblage. 5. Fixez le câble d’alimentation au boîtier de câblage à l’aide du connecteur appr

Comments to this Manuals

No comments