INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
QL100 Series Range Hood
IMPORTANT SAFETY INSTRUCTIONS
WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Use with approved cord-connection kit only.
8 . To reduce the risk of fire, use only metal ductwork.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal t ray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PA N - Yo u may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. Yo u can fight the fire with your back to an exit.
* Based on “Kitchen Firesafety Tips” published by NFPA.
IMPORTANT SAFETY INSTRUCTIONS
1. Fo r indoor use only.
2. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
3 . To reduce the risk of fire or electrical shock, this range hood
should not be used with an additional speed control device.
4 . To reduce the risk of shock, disconnect power before servicing.
5 . To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside.
6. Your hood motor has a thermal overload which will automati-
cally shut off the motor if it becomes overheated. The motor will
restart when it cools down. If the motor continues to shut off and
restart, have the hood serviced.
PLAN THE INSTALLATION
Recommended mounting height is 18 to 24” from the bottom of the
range hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall
cabinet. If the hood must be mounted directly to a wall, secure the
hood to wall studs.
All wiring must comply with local codes and the unit must be properly
grounded. The hood is connected to a 110-120vAC lighting circuit
(15 amp) in the circuit breaker or fuse box.
This range hood is “Convertible it may be installed as a ducted
or as a non-ducted unit.
IF THE RANGE HOOD IS TO BE NON-DUCTED:
Purchase non-ducted (duct-free) charcoal filter Model BPQTF.
IF THE RANGE HOOD IS TO BE DUCTED:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
For 7” round ductwork installation, use 7” round damper, Model
BP87 (97010792) Purchased damper separately.
!
INTENDED FOR DOMESTIC COOKING ONLY
!
Register your product online at: www.broan.com/register
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - QL100 Series Range Hood

INSTALLATION INSTRUCTIONSREAD & SAVE THESE INSTRUCTIONS!QL100 Series Range HoodIMPORTANT SAFETY INSTRUCTIONSWARNING – TO REDUCE THE RISK OF FIRE,

Page 2 - FIGURE 3

10CONEXIONES DE CABLEADOTodas las conexiones de cableado deben cumplir con el código local y la unidad debe estar apropiadamente conectada a tier

Page 3 - INSTALLATION

11PIEZAS DE SERVICIONO. NO. CODIGO PIEZA DESCRIPCION 1 R680508 Placa de conducto redondo de 17,78 cm (7 pulg.) 2 R99360244 Botón, Blan

Page 4 - HOOD WIRING

GARANTIALas especificaciones del producto están sujetas a cambio sin previo aviso.Rev. 2/12, No de parte 628029GGARANTÍA BROAN-NUTONE LIMITADA POR UN

Page 5 - SERVICE PARTS

2ELEC. K.O.CL12"CL7/8"6"7"DIA3/4"2"19"1"5"CUTOUT DIMENSIONSTOPVIEWBACKVIEWRANGEHOODREMOVE BOTH3¼" x

Page 6 - WARRANTY

3PREPARATION1. Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay out the range hood’s mounting holes, wiring access and ductwork

Page 7 - INSTRUCCIONES DE INSTALACION

4WIRING CONNECTIONSAll wiring connections must comply with local codes and the unit must be properly grounded.1. Make sure box connector is secure.2.

Page 8 - FIGURA 3

5SERVICE PARTSKEY NO. PART NO. DESCRIPTION 1 R680508 7-in. Round Duct Plate 2 R99360244 Knob, White (2 req.) R99360247 Knob, Biscuit (2 re

Page 9 - INSTALACIÓN

Product specifications subject to change without notice.Rev. 2/12, Part No. 628029GWARRANTYBROAN-NUTONE ONE YEAR LIMITED WARRANTYBroan-NuTone warrants

Page 10 - LA CAMPANA

INSTRUCCIONES DE INSTALACION¡LEA Y GUARDE ESTAS INSTRUCCIONES!INSTRUCCIONES IMPORTANTES DE SEGURIDADCUIDADO – PARA REDUCIR EL RIESGO DE FUEGO, DESCAR

Page 11 - PIEZAS DE SERVICIO

8QUITE AMBAS TAPAS DEAGUJEROS PREPUNZADAS,LA DE 8,26 cm x 25, 4 cm Y ELMEDIO CIRCULO DE 17,8 cmDE DIAMETROTAPA DE TECHOTECHOCODOAJUSTABLECONDUCTOCIRCU

Page 12 - GARANTIA

9PREPARACION1. Use los dibujos dimensionales (FIGURAS 1 - 3) para disponer los orificios de montaje de la campana, acceso del cableado y conductos, m