Broan QTR070 User Manual

Browse online or download User Manual for Household fans Broan QTR070. Broan QTR070 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
MODEL QTR070
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualied person(s) in accordance with all applicable codes
and standards, including re-rated construction codes and
standards.
4. Sufcient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specication label on product for further informa-
tion and requirements.
MODEL QTR070
ULTRA SILENT
TM
FAN
READ AND SAVE THESE INSTRUCTIONS
WARRANTY
Installer: Leave this manual with the homeowner.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See “Connect Wiring” for details.
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or repair
(other than by Broan-NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as
specied for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NU-
TONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the ex-
clusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you.
This warranty gives you specic legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identication and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
To register this product visit:
www.broan.com
CLEANING & MAINTENANCE
For quiet and efcient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - ULTRA SILENT

Page 1MODEL QTR070WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in the

Page 2 - PLAN THE INSTALLATION

Page 2MODEL QTR070TYPICAL INSTALLATIONSHousing mounted to I-joists. Use I-joist spacer block (provided).Housing mounted to joists.Housing mounted to

Page 3 - INSTALL HOUSING & DUCT

Page 3MODEL QTR0705. Connect electrical wiring. Run 120 VAC house wiring to installation location. Use proper UL approved connector to secure hous

Page 4 - INSTALL GRILLE

Page 4MODEL QTR070SERVICE PARTS99044095C Key No. Part No. Description 1 97016466 Housing 2 97016449 Duct Connector-4” 3 98010102 Wiring

Page 5 - VENTILADOR

Página 5MODELO QTR070ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENTES PRECAUC

Page 6 - INSTALACIÓN

Página 6MODELO QTR070INSTALACIONES TÍPICASMontaje de cubierta en viguetas “I”. Utilice un taco separador de viguetas “I” (suministrado).Montaje de c

Page 7 - Y EL CONDUCTO

Página 7MODELO QTR0705. Conecte los cables eléctricos. Extienda el cableado de la casa de 120 V CA al lugar de la instalación. Utilice una conexió

Page 8 - INSTALE LA REJILLA

Página 8MODELO QTR070PIEZAS DE REPUESTO99044095C Clave n.o Pieza n.o Descripción 1 97016466 Cubierta 2 97016449 Conector del conducto (4 pul