5. CHOOSETHE OPENING(S)(INTERNALBLOWER(S)HOOD ONLY)
Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.
VERTICAL DISCHARGE
HORIZONTAL DISCHARGE
NOTE: For ducted installation only.
O °O
O °O
HR0021
O
O
Punch out the appropriate electrical knockout
hole on top (A) or back (B) of the hood.
Install the wire clamp (included in parts bag).
NOTE: For a non-ducted installation, punch
out the back electrical knock-out (B).
A
HD0250
B
6. REMOVEFILTERSANDTHE GREASEDRIPRAIL
A. Remove tape on filters.
Remove filters from hood and set aside.
NOTE: It is recommended to start with the
center one.
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set aside.
A B
7. REMOVETHEADAPTER(INTERNAL BLOWERHOODSONLY)
Remove the adapter (1), or adapter/damper, taped inside the hood.