Broan 349BR Use and Care Manual

Browse online or download Use and Care Manual for Household fans Broan 349BR. Broan 349BR Use and Care Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MODEL 349BR
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. The wiring must be permanent. DO NOT USE AN EXTENSION
CORD! Use 14 GA. MINIMUM copper wire. Although the Powered
Attic Ventilator may be wired directly to power, we advise that
some type of shut off switch be installed in the line. Please see
the section on electrical wiring for suggested wiring diagrams
and instructions.
7. To reduce the risk of electric shock, do not use this fan with
any solid-state speed control device.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. Fan is equipped with a thermostat which may start fan
automatically. To reduce risk of injury or electric shock while
servicing or cleaning unit, switch power off at service panel
and lock service panel to prevent power from being switched
on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
5. Home Ventilating Institute (HVI) recommends one square foot
of open air inlet per 300 cfm of fan capacity. The best location
for these air intake vents are under the eaves with direct access
to the attic. Failure to provide these intakes could cause natural-
draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condition
with all attic ventilators and will not cause any damage to the
structure. We recommend that you do not store any valuable
articles directly under the fan opening in the roof. During extreme
rain and wind storms you may want to turn on your attic ventilator
to prevent excess moisture accumulation in your attic.
7. Records show, under ideal conditions, exposed galvanized steel
can remain rust free up to 100 years. For best protection, the
exposed portion of the roof sheet should be painted, especially
in areas of unusually high industrial air pollution. Follow paint
manufacturer's instructions for good adhesion.
8. This ventilator is intended for roof installation. The Broan Model
353 Gable Mount Ventilator is available for side wall applications.
9. The dome may be painted with a high-quality paint. Follow the
paint manufacturer's recommendations for powder-coated steel.
10. Please read specification label on product for further information
and requirements.
ROOF-MOUNT
POWERED ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
q
Slotted Screwdriver
q
Drill
q
1/4" Drill Bit
q
Sabre Saw or Keyhole Saw
q
Hammer
q
Ruler
q
Pencil
q
Utility Knife
q
Pry Bar (to remove roofing nails)
q
Roofing Cement
q
Galvanized Roofing Nails (1¾" min.)
q
Electrical Supplies (to comply with codes)
TOOLS AND MATERIALS REQUIRED
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - POWERED ATTIC VENTILATOR

MODEL 349BRPage 1WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in the ma

Page 2 - INSTALLATION

MODÈLE 349BRPage 10Garantie limitée de un anGARANTIE DU PROPRIÉTAIRE : Broan-NuTone garantit à l’acheteur original de ses produits que ces de

Page 3 - MODEL 349BR

MODELO 349BRPágina 11ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENTES PRECAUCI

Page 4 - ADJUSTING THE THERMOSTAT

MODELO 349BRPágina 121. Ubique el ventilador en el centro de la pendiente posterior del techo. Colóquelo tan alto en el techo como sea posi

Page 5 - WARRANTY

MODELO 349BRPágina 136. Recorte las tejas dentro del círculo.7. Reemplace la plantilla sobre el orificio guía y dibuje un círculo de 14 7/8 pulg. (

Page 6 - GRENIER MONTÉ SUR LE TOIT

MODELO 349BRPágina 14IMPORTANTE: No monte la caja de conexiones cerca de la fuente de calor.1. Monte la caja de conexiones en una viga cercana para

Page 7

MODELO 349BRPágina 151234765GARANTÍA Garantía limitada de un añoGARANTÍA DEL PROPIETARIO: Broan-NuTone garantiza al comprador consumidor origi

Page 9 - RÉGLAGE DU THERMOSTAT

MODEL 349BRPage 21. Locate the ventilator at the center of the rear slope of the roof. Place it as high on the roof as possible. The location should

Page 10 - PIÈCES DE RECHANGE

MODEL 349BRPage 36. Cut out the shingles inside of the circle.7. Replace template over guide hole and draw a 14 7/8"diameter circle on

Page 11 - ÁTICO MONTADO EN EL TECHO

MODEL 349BRPage 4IMPORTANT: Do not mount outlet box near heat source.1. Mount the outlet box to a nearby rafter so that the outlet box is higher tha

Page 12 - INSTALACIÓN

MODEL 349BRPage 5SERVICE PARTS KEY NO. PART NO. DESCRIPTION 1 0705B-000 Cover 2 0706B-000 Motor 3 0707B-000 Blade 4 0708B-000 Conduit

Page 13 - Página 13

MODÈLE 349BRPage 6AVERTISSEMENT AFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES, SUIVEZ CES DIRECTIVES :1. N’

Page 14 - AJUSTE DEL TERMOSTATO

MODÈLE 349BRPage 71. Choisissez un emplacement pour le ventilateur au centre du toit sur la pente arrière. Placez-le le plus haut possible sur le to

Page 15 - PIEZAS DE SERVICIO

MODÈLE 349BRPage 86. Taillez les bardeaux à l’intérieur du cercle.7. Replacez le gabarit sur l’avant-trou et tracez un cercle de 35,7 cm (14 7/8 po

Page 16 - 99527122A

MODÈLE 349BRPage 9IMPORTANT : Ne fixez pas la boîte électrique près d’une source de chaleur.1. Fixez la boîte électrique plus haute que le moteur du

Comments to this Manuals