Broan NUTOAN 336 User Manual

Browse online or download User Manual for Unknown Broan NUTOAN 336. Broan NUTOAN 336 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
READ AND SAVE THESE INSTRUCTIONS
MODEL 336
EXTERIOR MOUNTED BLOWER
FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS
FOR USE WITH "BEST BY BROAN" K-210A OR K-260A SERIES RANGE HOODS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
MODEL VOLTS AMPS CFM DUCT SIZE
336 120 3.8 1500 10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL 336
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER PLATE
MODEL
336
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
DUCT
OPENING
COVER PLATE
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
WARNING
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
MODEL 335
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER
PLATE
PLAN THE INSTALLATION
1. Locate the blower so the length of the duct run and number
of elbows needed are kept to a minimum.
ALL INSTALLATIONS
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
2. Where possible, blower should be centered between wall
studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be running
through the wall.
NOTE: Horizontal discharge requires relocation of the duct
opening cover plate. See hood manual for instructions.
MODEL
336
EXTERIOR
BLOWER
::
rangehoods
.
com
Call 1-800-667-8721 anywhere in the US and Canada
-
www.rangehoods.com
U N L I M I T E D
Broan at
::rangehoods.com
is a division of
kitchen::accessories
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - MODEL 336

READ AND SAVE THESE INSTRUCTIONSMODEL 336EXTERIOR MOUNTED BLOWERFOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODSFOR USE WI

Page 2 - LOCATION

102929½"74,9 cm74,9 cmMontante de la paredOrificioOrificiode 11 pode 11 po(27,9 cm)(27,9 cm)de dide diá.Orificio de 1Orificio de 1¼ po po(3,2 cm)

Page 3 - INSTALL THE BLOWER

11INSTALE DEL VENTILADORINSTALACIONES DE TECHOINSTALE DEL VENTILADORINSTALACIONES DE PAREDNEGRO AAZULLÍNEA DEENTRADA120 VCABLANCOAMARRÓNTIERRA ALTORNI

Page 4 - Model 336

12 99042800DUSO Y CUIDADODesconecte la fuerza eléctrica y bloquee el panel de servicioantes de limpiar o hacer el servicio en la unidad.LIMPIEZASaque

Page 5 - MODÈLE 336

211" dia.hole20½"11" dia.hole1"ØØ911/16"20½"ØØ18"125/8"18"1211/16"1¼" dia. hole1¼" dia. ho

Page 6 - ::rangehoods.com

31. Remove the cover and screws.2. Attach an appropriate U.L. approved cable connectorin the hole at the rear of the wiring box.3. Remove roofing nail

Page 7

4 99042800DUSE AND CAREDisconnect electrical power supply and lock out servicepanel before cleaning or servicing this unit.CLEANINGRemove cover and ca

Page 8

5MODEL335EXTERIORBLOWERWALL HOODCANOPY(island canopyavailable)10" ROUND DUCTSOFFITROUGH-INPLATE24" or 27"18"10" ROUND ELBOWDI

Page 9 - MODELO 336

620½"1"1"2,52,5cmcmØØ2020½"52,1 cm52,1 cmØØ18"18"38,1 cm38,1 cm1211/16"18 po45,7 cm12121111/16 16 popo32,2 cm32,2 c

Page 10 - INSTALACION

7INSTALLATION DU VENTILATEUR INSTALLATION DU VENTILATEURNOIR AVEC BLEUARRIVÉE120 VCABLANCAVECBRUNFIL DETERRE SURVIS DE MISEÀ LA TERRE1. Enlevez le c

Page 11 - INSTALE DEL VENTILADOR

8 99042800DUSAGE ET ENTRETIENDébrancher le courant et le panneau de service avant denettoyer ou d’effectuer une réparation ou un entretien dansce vent

Page 12 - Modelo 336

9MODEL335EXTERIORBLOWERWALL HOODCANOPY(island canopyavailable)10" ROUND DUCTSOFFITROUGH-INPLATE24" or 27"18"10" ROUND ELBOWDI

Comments to this Manuals

No comments