LOSONE SELECT
®
L100 SERIES L150 SERIES
L200 SERIES L250 SERIES L300 SERIES
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3.Installationworkandelectricalwiringmustbedonebyaqualied
person(s) in accordance with all applicable codes and standards,
includingre-ratedconstructioncodesandstandards.
4.Sufcientairisneededforpropercombustionandexhaustingof
gasesthroughtheue(chimney)offuelburningequipmenttopre-
vent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7.Toreducetheriskofre,useonlymetalductwork.
8. Models L100, L150, L200, L250, and L300 only:
If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
aGFCI(GroundFaultInterrupter)-protectedbranchcircuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
CAUTION
1.Forgeneralventilatinguseonly.Donotusetoexhausthazard-
ousorexplosivematerialsandvapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3.Pleasereadspecicationlabelonproductforfurtherinformation
and requirements.
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
This manual is divided into sections as follows:
“WARRANTY”
“TYPICAL INSTALLATION”
Thissectionshowsacommoninstallationinnewandexisting,
frame construction.
-Mounting(newconstruction)
-Mounting(existingconstruction)
-Wiring
-Ducting(horizontalblowerdischarge)
“MOUNTING OPTIONS”
“WIRING OPTIONS”
-WiringPlatePosition
“DUCTING OPTIONS”
-BlowerDischargePositions
-Ducting(verticalblowerdischarge)
“USE AND CARE”
“SERVICE PARTS”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTonewarrantstotheoriginalconsumerpurchaserofits products thatsuch
products will be free from defects in materials or workmanship for a period of one year
from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Duringthisone-yearperiod,Broan-NuTonewill,atitsoption,repairorreplace,without
charge, any product or part which is found to be defective under normal use and ser-
vice.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND
TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper
maintenanceorrepair(otherthanbyBroan-NuTone),faultyinstallationorinstallation
contrary to recommended installation instructions.
Thedurationofanimpliedwarrantyislimitedtotheone-yearperiodasspeciedforthe
expresswarranty.Somestatesdonotallowlimitationonhowlonganimpliedwarranty
lasts, so the above limitation may not apply to you.
BROAN-NUTONE’SOBLIGATIONTOREPAIRORREPLACE,ATBROAN-NUTONE’S
OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER
THIS WARRANTY. BROAN-NUTONE SHALLNOT BELIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITHPRODUCTUSEORPERFORMANCE.Somestatesdonotallowtheexclusion
or limitation of incidental or consequential damages, so the above limitation may not
apply to you.
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights,which
vary from state to state. This warranty supersedes all prior warranties.
Toqualifyforwarrantyservice,youmust(a)notifyBroan-NuToneattheaddressstated
belowortelephone:1-800-637-1453,(b)givethemodelnumberandpartidentication
and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI U.S.A.
53027(1-800-637-1453)
In Canada, contact: Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga,
OntarioL5T1H9(1-888-882-7626)
LOSONE SELECT
®
VENTILATORS
Ceiling/Wall Mount
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - VENTILATORS

Page 1LOSONE SELECT® L100 SERIES L150 SERIESL200 SERIES L250 SERIES L300 SERIES !WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

Page 2 - TYPICAL INSTALLATION

INSTALLATION TYPIQUEMONTAGE (Construction en cours)SOLIVE DE PLAFOND (16 po / 40,6 cmcentre) CONDUIT CIRCULAIRE*GRILLE(en polymère)À installer après l

Page 3 - USE AND CARE

OPTIONS DE MONTAGEOPTIONS DE CÂBLAGEOPTIONS D’INSTALLATION DES Supports en position préas-semblée(Sortieparallèleauxsolives)(Bâtiment en cours de c

Page 4 - SERVICE PARTS SERVICE PARTS

1234567891011121314171819192020212324161542525164422PIÈCES DE RECHANGE PIÈCES DE RECHANGE LÉGENDE No DE RÉF. DESCRIPTION 1 97014725 Boîtier (L100

Page 5 - VENTILADORES

Page 2LOSONE SELECT® L100 SERIES L150 SERIESL200 SERIES L250 SERIES L300 SERIES TYPICAL INSTALLATIONMOUNTING (New Frame Construction)CEILING

Page 6 - INSTALACIÓN TÍPICA

Page 3LOSONE SELECT® L100 SERIES L150 SERIESL200 SERIES L250 SERIES L300 SERIES 12¼"91/2"to101/2"ADUSTABLE FOR VARIOUS CEILING

Page 7 - USO Y CUIDADO

Page 4LOSONE SELECT® L100 SERIES L150 SERIESL200 SERIES L250 SERIES L300 SERIES SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 1

Page 8 - SERIE L100 SERIE L150

Página 5LOSONE SELECT® SERIE L100 SERIE L150SERIE L200 SERIE L250 SERIE L300 !ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO,

Page 9 - VENTILATEURS

Página 6LOSONE SELECT® SERIE L100 SERIE L150SERIE L200 SERIE L250 SERIE L300 INSTALACIÓN TÍPICAMONTAJE (Estructura nueva)VIGUETA DEL TECHO(se

Page 10 - INSTALLATION TYPIQUE

Página 7LOSONE SELECT® SERIE L100 SERIE L150SERIE L200 SERIE L250 SERIE L300 12¼"91/2"to101/2"ADUSTABLE FOR VARIOUS CEILING THI

Page 11 - UTILISATION ET ENTRETIEN

1234567891011121314171819192020212324161542525164422PIEZAS DE SERVICIO PIEZAS DE SERVICIO CLAVE Nº. PIEZA Nº. DESCRIPCIÓN 1 97014725 Conjunto del

Page 12 - SÉRIE L100 SÉRIE L150

!AVERTISSEMENTPOUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES, OBSERVEZ CE QUI SUIT:1. Utilisezcetteunitéseulem

Comments to this Manuals

No comments