MODELS RMIP33 AND RMIP45
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register
SV05861 rev. I
HB0031
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - MODELS RMIP33 AND RMIP45

MODELS RMIP33 AND RMIP45INTENDED FOR DOMESTIC COOKING ONLYINSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12

Page 2 - WARNING WARNING

- 10 -16. DUCTING CONNECTION (ALL BLOWERS)A. When there is access to the top of the hood, connect ductwork and seal connections with duct tape after S

Page 3 - (roof cap)

- 11 -Secure the blower by installing 2 more no. 8 x 3/8’’ screws for the P5 blower and 4 more no. 8 x 3/8’’ screws for P8 intothe locations shown in

Page 4 - IN-LINE AND EXTERIOR BLOWERS

- 12 -Grease filters and impeller(s).The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution. Grea

Page 5 - 2. PREPARE THE INSTALLATION

22. OPERATIONBLOWERThe blower is operated using two (2) controls or with the RMIPWC optional wall control.Use the red, lighted on/off switch to start

Page 6 - 4. CUSTOM HOOD PREPARATION

KEY PART MODELNO. NUMBERDESCRIPTION33 45RANGEMASTER LOGOFILTER CLIPTHERMOSTATSPEED CONTROLSCREW NO. 8-32 x 1/2’’, QUADREXMALE CONNECTORFEMALE CONNECTO

Page 7 - NOMINAL WIDTH

KEYNO.PART NUMBER DESCRIPTION QTY.- 15 -SERVICE PARTS1234567891011121314151617181920212223SV13296SV03500SV12997SV03577SV02160SV01869SV01857SV01582SV1

Page 8 - KNOCKOUT

212223232024251191817161513691011121445KEYNO.PART NUMBER DESCRIPTION QTY.12345678910111213141516171819202122232425SV14971SV13296SV03500SV14975SV03577

Page 9 - 1) Ground screw

GUIDE D’INSTALLATIONCONÇUS POUR LA CUISSON DOMESTIQUE SEULEMENTINSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE.PROPRIÉTAIRE : DIRECTIVES D’UTILISATION

Page 10 - 17. INSTALL THE INSERT

- 18 -AVERTISSEMENT AVERTISSEMENTAFIN DE RÉDUIRE LES RISQUES D’INCENDIE,D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES,SUIVEZ LES DIRECTIVES SUIVANTES :1

Page 11 - Dual blower (P8)

HL0067- 19 -MODÈLES RMIP33 ET RMIP45 - SYSTÈME DE MODULEDE HOTTE ENCASTRABLE - VENTILATEURS INTÉRIEURSDosseret Série RMP(Recouvrement de muren acier i

Page 12 - 20. INSTALL FILTERS

WARNING WARNING- 2 -TO REDUCE THE RISK OF FIRE, ELECTRICSHOCK OR INJURY TO PERSONS, OBSERVETHE FOLLOWING:1. Use this unit only in the manner intended

Page 13 - 21. USE AND CARE (CONT’D)

- 20 -HL0068Modèle 421(Volet intérieur10 po rond vert.)Recommandépour utilisationavec ventilateursextérieursModèle 410(Conduit de 10 po rond standard

Page 14 - WARRANTY

1. SÉLECTIONNER L’OPTION VENTILATEUR ET NSTALLER LES CONDUITSCe module de hotte encastrable fonctionne autant avec un ventilateur intérieur, en ligne

Page 15

- 22 -3. INSTALLER LE DOSSERET (OPTIONNEL)Il est recommandé d’installer le dosseret avant le module de hotte encastrable. L’armoire couvrira les vis d

Page 16

- 23 -8. DÉCOUPER LE TROU DANS LA BASE DE L’ARMOIRESi ce n’est pas déjà fait, découper le trou dans la base de l’armoire, aux dimensions indiquées ci-

Page 17 - MODÈLES RMIP33 ET RMIP45

- 24 -11. INSTALLER LE DÉVIATEUR (VENTILATEUR INTÉRIEUR)Installer le déviateur tel qu’il est illustré.NOTE : Afin d’empêcher que le déviateur glisse à

Page 18 - ATTENTION

13. BRANCHEMENTS ÉLECTRIQUES (TOUS LES VENTILATEURS)Placer le module sous son armoire. Passer le fil d’alimentation électrique par le trou du dessus d

Page 19 - SYSTÈME DE MODULE

- 26 -16. RACCORDEMENT DES CONDUITS (TOUS LES VENTILATEURS)A. Si l’accès au dessus de l’armoire demeure ouvert, aller au point 17 Installer le module,

Page 20

HD0044HD0045Ventilateur simple (P5)Ventilateur double (P8)18. INSTALLER LE VENTILATEUR (VENTILATEUR INTERIEUR) (SUITE)Installer 4 vis n° 8 x 3/8 po au

Page 21 - 2. PRÉPARER L’INSTALLATION

- 28 -Filtres et roue(s) de ventilateur.Les filtres, la gouttière et la ou les roue(s) de ventilateur doivent être fréquemment nettoyés. Utiliser de l

Page 22 - AVERTISSEMENT

- 29 -HEAT SENTRYMCVotre module de hotte encastrable est équipé d’un capteur de température appelé Heat Sentry. Ce capteur mettra enmarche automatique

Page 23 - HD0084F

HL0067- 3 -RMP Series Backsplash(Stainless Steel wallcovering with warmingshelves. Optional)RML3336S, RML3342S,RML4548S, RML4554S orRML4560SCustom Hoo

Page 24

N° N° DE MODÈLERÉF. PIÈCEDESCRIPTION33 45- 30 -PIÈCES DE REMPLACEMENTGARANTIEGARANTIE LIMITÉE DE UN AN DES PRODUITS BROAN ELITEBroan-NuTone LLC (Broan

Page 25

- 31 -PIÈCES DE REMPLACEMENTN° DE N° DE LARÉF. PIÈCEDESCRIPTION QTÉ1234567891011121314151617181920212223SV13296SV03500SV12997SV

Page 26 - 17. INSTALLER LE MODULE

- 32 -PIÈCES DE REMPLACEMENTN°DE N°DE LA RÉF. PIÈCE DESCRIPTION QTÉ12345678910111213141516171819202122232425SV14971SV13296S

Page 27 - Ventilateur double (P8)

MANUAL DE INSTALACIÓNCONCEBIDO SÓLO PARA USO DOMÉSTICOINSTALADOR: DEJAR ESTE MANUAL AL PROPIETARIO.PROPIETARIO : INSTRUCCIONES DE UTILIZACIÓN Y MANTEN

Page 28 - 20. INSTALLER LES FILTRES

- 34 -ADVERTENCIA ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO,DESCARGA ELÉCTRICA, O LESIONES A PERSONAS, CUMPLA LOS SIGUIENTES PUNTOS:1. Solamente u

Page 29 - 22. FONCTIONNEMENT

- 35 -Placa antisalpicadurasSerie RMP(Cubierta para paredde acero inoxidable conestantes para calentamiento.Opcional.)Modelo P5 ventilador simple (500

Page 30 - GARANTIE

- 36 -HL0068Modelo 421 (10” Redondo.vertical, enlínea interior)Recomandadopara utilizacióncon ventiladoresexterioresModelo 410 conductode 10” redondo(

Page 31

- 37 -1. SELECCIONE LA OPCIÓN VENTILADOR Y INSTALE LOS CONDUCTOSEste dispositivo funciona tanto con un ventilador exterior, con un ventilador en línea

Page 32

- 38 -3. INSTALE LA PLACA ANTISALPICADURAS (OPCIONAL)Se recomienda instalar la placa antisalpicaduras antes de introducir la campana extactora. La cam

Page 33 - MODELOS RMIP33 Y RMIP45

- 39 -8. CORTE EL ORIFICIO EN LA BASE DE LA CAMPANA EXTRACTORASi no está hecho, corte un orificio en la base de la campana, utilizando las dimensiones

Page 34 - PRECAUCIÓN

- 4 -HL0068RMP Series Backsplash(Stainless Steel wallcovering with warmingshelves. Optional)RML3336S, RML3342S,RML4548S, RML4554S or RML4560SCustom Ho

Page 35 - VENTILADORES INTERIORES

- 40 -11. INSTALE EL DESVIADOR (VENTILADOR INTERIOR)Instale el desviador tal como ilustrado.NOTA : Para que el desviador no se salga de la bandeja de

Page 36

13. CONEXIÓN ELÉCTRICA (TODOS LOS VENTILADORES)Coloque el dispositivo debajo de la campana extractora instalada. Introduzca el cable por el orificio s

Page 37 - 2. PREPARE LA INSTALACIÓN

- 42 -16. CONEXIÓN DEL CONDUCTO (TODOS LOS VENTILADORES)A. Si existe un acceso por la parte superior de la campana, conecte el conducto y selle las ju

Page 38 - ADVERTENCIA

18. INSTALACIÓN DEL VENTILADOR (INTERIOR) (CONTINUACIÓN)Instale 4 tornillos n.° 8 x 3/8’’ en el lugar que indica la foto de abajo (ventilador simple o

Page 39 - EXTRACTORA (OPCIONAL)

- 44 -19. LUCES HALÓGENASEsta campana utiliza bombillas halógenas de 50 W (120 V, 50 W, PAR 20) (vendidas por separado). Instale la bombilla girando e

Page 40

- 45 -HEAT SENTRY™Su dispositivo esta equipado con Heat Sentry. Este termostato tiene un mecanismo que se encenderá ó acelerará elventilador si se det

Page 41

REF. N.° DE MODELON.° PIEZADESCRIPCIÓN33 45LOGOTIPO RANGEMASTER GRAPA FILTROSTERMOSTATOCONTROL DE VELOCIDADTORNILLO N.°8-32 x 1/2’’, QUADREXCONNECTADO

Page 42

- 47 -REPUESTOSN.° REF. N.° PIEZA DESCRIPCIÓN CTD1234567891011121314151617181920212223SV13296SV03500SV12997SV03577SV02160SV01869SV01857SV01582SV14973

Page 43 - Ventilador doble (P8)

REPUESTOSN.° REF. N.° PIEZA DESCRIPCIÓN CTD12345678910111213141516171819202122232425SV14971SV13296SV03500SV14975SV03577SV01582SV02160SV01857SV01766SV

Page 44 - 21. MANTENIMIENTO

- 5 -1. SELECT BLOWER OPTION AND INSTALL DUCTWORKEither an interior or exterior blower or in-line blower may be used with this insert. The insert mode

Page 45 - 22. FUNCIONAMIENTO

- 6 -3. INSTALL BACKSPLASH (OPTIONAL)It is recommended to install the backsplash before the custom hood insert. The custom hood will cover the backspl

Page 46 - GARANTÍA

- 7 -8. CUT THE HOLE IN CUSTOM HOOD BASEIf it is not done yet, cut a hole in the bottom of the cabinet, usingthe dimensions shown beside. NOTES : 1. T

Page 47

- 8 -11. INSTALL THE DEVIATOR (INTERIOR BLOWER)Install the deviator as shown.NOTE : To prevent the deviator from sliding out of the rough-in plate, pu

Page 48

- 9 -13. CONNECT WIRING (ALL BLOWERS)Connect cable into wiring box using provided wire connectors.Connect wires as follow: BLACK to BLACK, WHITE to WH