Broan 332H User Manual

Browse online or download User Manual for Unknown Broan 332H. Broan 332H Installation Instructions

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page Lm
1
MODEL
331H
or 332H
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
DUCT
OPENING
COVER PLATE
MODEL
331H
or 332H
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER
PLATE
MODEL 331H or 332H
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
24" or 27"
18"
ROUGH-IN
PLATE
DUCT
OPENING
COVER PLATE
READ AND SAVE THESE INSTRUCTIONS
FOR USE WITH RANGEMASTER HOODS AND ECLIPSE DOWNDRAFT VENTILATORS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum for Model 332H or 3 AMPS minimum
for Model 331H.
1. Locate the blower so the length of the duct run and number of
elbows and transitions needed are kept to a minimum.
Please note - when using blower with the Broan Eclipse
Downdraft: The downdraft has a 3¼" x 10" discharge.
Transitions are available to connect it to the 10" round
inlet on this exterior-mounted blower.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
331H 120 2.4 600 10 " DIA.
332H 120 5.7 900 10" DIA.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 3
MODELS 331H & 332H
EXTERIOR MOUNTED BLOWER
SPECIFICATIONS
PLAN THE INSTALLATION
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
2. Where possible, blower should be centered between wall
studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be running
through the wall.
4. Be sure that there is enough space for any transitions that may
be needed between the blower and the connecting ductwork.
5. For best performance, locate transitions nearest to ventilator
(i.e. downdraft).
NOTE: Horizontal discharge requires relocation of the duct open-
ing cover plate. See hood manual for instructions.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - EXTERIOR MOUNTED BLOWER

Page Lm1MODEL331Hor 332HEXTERIORBLOWERWALL HOODCANOPY(island canopyavailable)10" ROUND DUCTSOFFITROUGH-INPLATE24" or 27"18"10"

Page 2

10PREPARE EL LUGAR DE LAINSTALACIÓNINSTALACIONES EN EL TECHOPREPARE EL LUGAR DE LAINSTALACIÓNINSTALACIONES EN LA PAREDTODAS LAS INSTALACIONES1. Ubique

Page 3 - INSTALL THE BLOWER

Page Lm111. Quite los clavos del techo de las 2/3 partes de las tejassuperiores que se encuentran alrededor del área de corte ylevante las tejas con c

Page 4 - SERVICE PARTS

12CLAVEN.º PIEZA Nº. DESCRIPCIÓN1 97011795 Conjunto de la caja de ventilación2 98008507 Regulador de tiro3 93260454 Tuerca para metales, #18-18 tipo U

Page 5

211" dia.hole29½"11" dia.hole1¼"dia. hole127/8"10¾"25"7¼"7¼"1¼"dia. hole91/8"91/8"Wall Stu

Page 6

1. Remove roofing nails from the upper 2/3 of theshingles around the cutout area and carefully lift theshingles to allow the back flashing sheet on th

Page 7 - INSTALLATION DU VENTILATEUR

4KEYNO. PART NO. DESCRIPTION1 97011795 Airbox Assembly2 98008507 Damper3 93260454 Sheet Metal Nut, #18-18 U-Type (7 req.)*4 99100484 Isolator (3 req.)

Page 8 - PIÈCES DE RECHANGE

Page Lm5MODEL331Hor 332HEXTERIORBLOWERWALL HOODCANOPY(island canopyavailable)10" ROUND DUCTSOFFITROUGH-INPLATE24" or 27"18"10"

Page 9 - MODELOS 331H Y 332H

61. Choisissez une position sur le mur extérieur. Assurez qu'il n'ya pas de colombage, tuyaux ou fils dans l'endroit qui seraouvert.PRÉ

Page 10 - 24¾"

Page Lm71. Retirez les premiers deux tiers des clous à toiture desbardeaux se trouvant autour de la surface de découpe puissoulevez délicatement les b

Page 11 - INSTALE EL VENTILADOR

8REPÈRE N° PIÈCE DESCRIPTION1 97011795 Boîte à air2 98008507 Clapet3 93260454 Écrou à tôle, n° 18-18 Type U (7)*4 99100484 Isolateur (3)5 99260477 Écr

Page 12 - PIEZAS DE REPUESTO

Page Lm9MODEL331Hor 332HEXTERIORBLOWERWALL HOODCANOPY(island canopyavailable)10" ROUND DUCTSOFFITROUGH-INPLATE24" or 27"18"10"

Comments to this Manuals

No comments