MODELS L400K • L500K
LOSONE SELECT
®
VENTILATORS
Ceiling/Wall Mount • 120V
READ AND SAVE THESE INSTRUCTIONS
Page 1
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
*Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“TYPICAL INSTALLATION”
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
“MOUNTING OPTIONS”
“WIRING OPTIONS”
-Wiring Plate Position
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (vertical blower discharge)
“USE AND CARE”
“SERVICE PARTS”
“WARRANTY”
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - VENTILATORS

Page 1MODELS L400K • L500KLOSONE SELECT®VENTILATORSCeiling/Wall Mount • 120VREAD AND SAVE THESE INSTRUCTIONSPage 1Installer: Leave this manual withth

Page 2 - TYPICAL INSTALLATION

Page 10MODELS L400K • L500KMODÈLESINSTALLATION TYPIQUEMONTAGE (Construction en cours)SOLIVE DEPLAFOND24 po (61cm centre)CONDUIT CIRCULAIRE DE10 po (2

Page 3 - MOUNTING OPTIONS

Page 11MODELS L400K • L500KMODÈLESOPTIONS DE MONTAGEOPTIONS DE CÂBLAGEOPTIONS D’INSTALLATION DES CONDUITSSupports en positionpréassemblée(Sortie para

Page 4 - WARRANTY

Page 12MODELS L400K • L500KMODÈLESPIÈCES DE RECHANGE PIÈCES DE RECHANGEGARANTIEGARANTIE LIMITÉE D’UN AN DE BROAN-NUTONEBroan-NuTone garantit à l’ache

Page 5 - VENTILADORES

Page 2MODELS L400K • L500KTYPICAL INSTALLATIONMOUNTING(New Frame Construction)CEILINGJOIST(24” centersshown)10” ROUND DUCTGRILLEInstall after ceiling

Page 6 - INSTALACIÓN TÍPICA

Page 3MODELS L400K • L500K21½"91/2" to101/2"21½"10 3/4" to11 3/4"MOUNTING OPTIONSWIRING OPTIONSDUCTING OPTIONS21½"

Page 7 - USO Y CUIDADO

Page 4MODELS L400K • L500KSERVICE PARTS SERVICE PARTSWARRANTYKEY NO. PART NO. DESCRIPTION1 97014744 Housing Assembly2 97014728 Mounting Bracket (2 re

Page 8 - GARANTIA

Page 5MODELS L400K • L500KMODELOSVENTILADORESLOSONE SELECT®Para montaje encielo raso/pared • 120 VLEA Y CONSERVE ESTAS INSTRUCCIONESPágina!ADVERTENCI

Page 9 - VENTILATEURS

Page 6MODELS L400K • L500KPáginaINSTALACIÓN TÍPICAMONTAJE (Estructura nueva)VIGUETA DEL TECHO(se muestran centros de24” (61 cm)PARRILLAInstale hastad

Page 10 - INSTALLATION TYPIQUE

Page 7MODELS L400K • L500K21½"11/8"MAX.21½"91/2" to101/2"21½"10 3/4" to11 3/4"12¼"11/2"to21/2"