MODEL RMDDRBK
REMOTE UP/DOWN CONTROL
For use with RMDD Series Downdraft Ventilators.
INSTALLATION
1. Using the template at right, lay out the 3-hole pattern on the counter top.
Mark the centers of the three holes to be drilled.
2. Carefully drill the three holes through the counter top. Be careful not to
damage or chip the counter top surface when drilling the holes.
3. Remove the control from the plastic bag. Line the control up with the three
holes and position the control so it is parallel with the front of the counter top.
4. Remove the two nylon thumbnuts from the plastic bag and thread onto the
two studs on the control from below the counter top. Hand tighten only.
WARNING: To reduce the risk of burns or ignition of clothing
by reaching across burners, the remote control must be
mounted at least 4" away from any cook top burner.
.250 DIA.
HOLES
.438
DIA.
HOLE
2.000
2.000
.750
.750
1.000
.625
.625
5. Remove the blower, clamp channels, and gearmotor cover from downdraft.
Remove the large panel to expose the downdraft's wiring.
When to use the Remote UP/DOWN Control
The Remote UP/DOWN Control should be used when your cooktop has a burner
that is within 4 inches of the UP/DOWN Button on the downdraft chimney.
The Remote UP/DOWN Control
can be used for convenient UP/DOWN opera-
tion of the downdraft chimney (even when a burner is more than 4 inches from
the UP/DOWN Button of the downdraft chimney).
How to use the Remote UP/DOWN Control
Do not place the remote control where it will interfere with cooking, where hot
pans could be set, or where hot liquids could be spilled on the control.
The Remote UP/DOWN Control disables the UP/DOWN function of the UP/
DOWN Button on the downdraft chimney.
6. At the lower right hand corner of downdraft, unplug the cable from the left
side of the wiring box.
7. Remove remote cable from the plastic bag and plug into back of control from below
counter top. Route cable through cabinet to lower right hand corner of downdraft and
through the clearance holes in the side of downdraft and wiring box. Plug cable into
circuit board plug, as shown.
8. Stuff excess cable out of the way, secure the cable so it is not damaged by items
stored in the cabinet, and reassemble downdraft.
CABINET
FLOOR
LOWER
RIGHT
SIDE
OF
DOWNDRAFT
CUT OUT ON DOTTED LINE
WIRING
BOX
REMOTE
CABLE
WIRING
BOX
Note: The downdraft up/down
control must be mounted into
the countertop, at least 4" from
the cooktop.
COUNTERTOP
UP / DOWN
CONTROL
COOKTOP
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Before servicing or cleaning unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service
panel.
2. Installation work and electrical wiring must be done by a qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.