Broan HRV100H User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
When the outside temperature is below 0°C (32°F), recovery (of heat or energy) creates
frost in the core. To maintain its proper operation, the unit is programmed to defrost the
recovery core. The defrost frequency varies according to the outside temperature.
Defrosting lasts 6 minutes. During the defrost cycle, the unit shifts to maximum speed and
the dampers close.
After defrosting, the unit returns to the operating mode selected by the user.
1.4 DEFROSTING
1.5 SPECIFICATIONS
Model 1001 ERV, 1001 HRV, HRV100H, ERV100HC
Width 30¼” (768 mm)
Height 20” (508 mm)
Depth 13¾” (349 mm)
Weight 65 lb (30 kg)
Electrical Supply 120 V, 60 Hz
Power Consumption 150 watts
Model 2001 ERV, 2001 HRV, HRV200H, ERV200HC
Width 30¼” (768 mm)
Height 20” (508 mm)
Depth 19” (483 mm)
Weight 73 lb (33 kg)
Electrical Supply 120 V, 60 Hz
Power Consumption 225 watts