Page 3
HOW TO SET SYSTEM LEVEL
Installer, homeowner, or building science expert may adjust Broan
SmartSense
®
ventilation system level.
1. System Level is only set in Master control. If home has more than
one installation then locate Master control; it is usually in master
bathroom or it should be clearly marked or documented.
2. Circle, mark or highlight System Level in Table A using home’s
square footage and number of bedrooms.
Note: Building science experts may calculate different rate based
on air infiltration measurements.
3. Circle, mark or highlight same System Level in Table B.
4. If home’s System Level is 30 then next steps are not necessary,
since System Level is set at factory to 30.
5. Put Master control in Program mode; press and hold SET button
for 3-seconds and then release it.
6. LED should be turning on and off every second (slow-blink); if it
is not then repeat step 5.
7. Press and release (tap) On paddle number of times from Table B.
If you tap On paddle too many times, tap Off paddle and System
Level will be reduced once for each Off paddle tap.
In order to reset System Level to 30, immediately after entering
Program mode (Steps 5-6), tap On paddle only once and then tap
Off paddle only
once.
If you lose On paddle counts, tap Off paddle 9 times or more then
tap On paddle twice; System Level will be at 30; proceed with On
paddle taps from Table B.
8. Exit Program mode; press and release SET button.
9. After exiting Program mode, LED will fast-blink a number of
times.
LED will fast-blink the same number of times in three sets with a
slight pause in between each set.
10. Count number of times LED fast-blinks in a set.
11. Compare number of times LED fast-blinks in a set to number for
System Level in Table B.
12. If they are the same then System Level is set accordingly;
otherwise, re-adjust System Level starting with step 5.
FEATURE SELECTIONS
Vacation Mode: Used only with Master control. Temporarily disables
Broan SmartSense
®
system. Master control will not automatically
turn on its fan or any other system fan. After Feature Selection
mode exit, Vacation mode is cancelled when Master control On
paddle is pressed.
Disabled Mode: Excludes fan from automatic ventilation usage.
Does not affect manual operation and its ventilation is credited
toward system level accumulation. Master control will not turn it on
for automatic ventilation requirement fulfillment. If Master control
is put in Disabled mode, it will not turn
on any
fans for automatic
ventilation and recommended indoor air quality ventilation level is
not assured.
Automatic-Off: Automatically turns fan off 60-minutes after it was
manually turned on.
Delayed-Off: Turns fan off 20-minutes after Off paddle was pressed
once. In order to turn fan off immediately, press Off paddle twice.
HOW TO NAVIGATE FEATURE SELECTION MODE
Refer to diagram. First, make sure fan and LED are off by pressing
and releasing Off paddle. Vacation/Disabled Feature Selection
mode entry is accomplished by pressing On paddle until LED turns
on and off every second (slow-blink). Automatic-Off/Delayed-Off
Feature Selection mode entry is accomplished using same method
with Off paddle. Once either Feature Selection mode is entered,
pressing and holding associated paddle displays Feature’s status
using LED. Press and release associated paddle to toggle feature on
or off. When finished, press and release SET button to exit Feature
TABLE A
Floor Area (ft
2
)
Bedrooms
0 - 1 2 - 3 4 - 5 6 - 7 > 7
< 1500
30 45 60 75 90
1501 - 3000
45 60 75 90 105
3001 - 4500
60 75 90 105 120
4501 - 6000
75 90 105 120 135
6001 - 7500
90 105 120 135 150
> 7500
105 120 135 150 165
TABLE B
System
Level
ON
Taps
Fast
Blinks
165 9 11
150 8 10
135 7 9
120 6 8
105 5 7
90 4 6
75 3 5
60 2 4
45 1 3
30 ON &
OFF or
OFF 9x
& ON 2x
2
Push to
turn ON
Push to
turn OFF
SmartSense
®
®
SET
button
ON PADDLE
OFF
PADDLE
Feature Selection Modes
ON Paddle
Vacation
or
Disabled
OFF Paddle
Automatic-Off
or
Delayed-Off
Press and hold paddle (approximately 10-seconds)
until LED displays slow-blink then release.
ON
Paddle
Vacation
OFF
Paddle
Disabled
ON
Paddle
Automatic
-Off
OFF
Paddle
Delayed
-Off
Press and hold paddle to display Feature status.
Press and release paddle to toggle Feature on or off.
When done, press and release SET button;
LED and fan should turn on and then off.
If fan is on, press OFF paddle.