Broan L1500 Installation Guide Page 1

Browse online or download Installation Guide for Unknown Broan L1500. Broan L1500 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
LOSONE SELECT
®
L900 SERIES • L1500 SERIES
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
LOSONE SELECT
®
VENTILATORS
Ceiling / Wall Mount
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
This manual is divided into sections as follows:
“WARRANTY”
“TYPICAL INSTALLATION”
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
“MOUNTING OPTIONS”
“WIRING OPTIONS”
-Wiring Plate Position
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (vertical blower discharge)
“USE AND CARE”
“SERVICE PARTS”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
Page 1
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of one year
from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and ser-
vice.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND
TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan-NuTone), faulty installation or installation
contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for
the express warranty. Some states do not allow limitation on how long an implied war-
ranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLU-
SIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE-NUTONE SHALL NOT
BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARIS-
ING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone-NuTone at the ad-
dress stated below or telephone: 1-800-637-1453, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At the
time of requesting warranty service, you must present evidence of the original pur-
chase date.
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027
(1-800-637-1453)
In Canada, contact: Broan-Nutone Canada, Inc., 1140 Tristar Drive Mississauga,
Ontario L5T 1H9 (1-888-882-7626)
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - VENTILATORS

Page 1LOSONE SELECT®L900 SERIES • L1500 SERIES!WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use

Page 2 - TYPICAL INSTALLATION

Page 10LOSONE SELECT®L900 SERIES • L1500 SERIESINSTALLATION TYPIQUEMONTAGE (Construction en cours)Appareil installé dans un bâtiment en cours de const

Page 3 - USE AND CARE

Page 11LOSONE SELECT®L900 SERIES • L1500 SERIESOPTIONS DE MONTAGEOPTIONS DE CÂBLAGEOPTIONS D’INSTALLATION DES CONDUITSDes écrous à six pans ¼-20 fixen

Page 4 - SERVICE PARTS SERVICE PARTS

Page 12LOSONE SELECT®L900 SERIES • L1500 SERIESPIÈCES DE RECHANGE PIÈCES DE RECHANGE99042812BLÉGENDE NO DE RÉF. DESCRIPTION1 97014853 Clapet2 99150415

Page 5 - VENTILADORES

Page 2LOSONE SELECT®L900 SERIES • L1500 SERIESTYPICAL INSTALLATIONMOUNTING (New Frame Construction)CEILINGJOIST(24” centersshown)12” ROUNDDUCTGRILLEFa

Page 6 - INSTALACIÓN TÍPICA

Page 3LOSONE SELECT®L900 SERIES • L1500 SERIES22"22"11/8"MAX.18"1½"to2½"MOUNTING OPTIONSWIRING OPTIONSDUCTING OPTIONSMou

Page 7 - USO Y CUIDADO

Page 4LOSONE SELECT®L900 SERIES • L1500 SERIESSERVICE PARTS SERVICE PARTSKEY NO. PART NO. DESCRIPTION1 97014853 Damper Flap2 99150415 Screw, #8B x ¼*

Page 8

Page 5LOSONE SELECT®L900 SERIES • L1500 SERIES!ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO,O LESIÓN A PERSONAS, OBSERVE LO SIGUIENT

Page 9 - VENTILATEURS

Page 6LOSONE SELECT®L900 SERIES • L1500 SERIESPáginaINSTALACIÓN TÍPICAMONTAJE (Estructura nueva)Unidad enviada de fábrica instalada en una estructura

Page 10 - INSTALLATION TYPIQUE

Page 7LOSONE SELECT®L900 SERIES • L1500 SERIESPáginaOPCIONES DE MONTAJEOPCIONES PARA LA CONEXIÓN ELÉCTRICAOPCIONES PARA LA COLOCACIÓN DECONDUCTOSLas t

Page 11 - UTILISATION ET ENTRETIEN

Page 8LOSONE SELECT®L900 SERIES • L1500 SERIESPáginaPIEZAS DE SERVICIO PIEZAS DE SERVICIOCLAVE Nº. PIEZA Nº. DESCRIPCIÓN1 97014853 Solapa del regulado

Page 12 - SÉRIE L900 • SÉRIE L1500

Page 9LOSONE SELECT®L900 SERIES • L1500 SERIES!AVERTISSEMENTPOUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUEOU DE BLESSURES PERSONNELLES, OBSERVE

Comments to this Manuals

No comments