TROUBLESHOOTING GUIDE
Read before calling Service Center.
PROBLEMS POSSIBLE CAUSES POSSIBLE REMEDY
1.Loss or decrease of
vacuum occurs.
Debris pail is completely full.
Obstruction in the hose. A blockage in the hose
can be determined by inserting the hose into any
wall inlet and, while power unit is running, check
each additional inlet for normal suction by holding
the palm of your hand over the open inlet. If normal
suction is felt at all other inlets, insert the hose
into a second inlet. If the blockage still exists it is
located in the hose. However, if the blockage
does not occur when the hose is changed, the
blockage is probably located in the tubing system
leading to the original inlet.
Obstruction in the tubing system inside the walls.
Wall inlet cover not properly sealed.
Exhaust tubing or vent clogged.
Empty debris pail as described on page 12.
Insert handle end of hose into utility valve at
power unit. Turn unit on. This will reverse normal
air flow through the hose and dislodge any clogs.
Insert hose end into any inlet with power unit running,
place the palm of your hand over the opposite
end of the hose. When you can feel the suction
increase, hold your hand over the hose end for a
few seconds and then quickly remove your hand.
This procedure repeated several times should
clear the obstruction. If the blockage is not
cleared, contact your nearest Service Center.
Check all wall inlet covers to be sure they are
closed and sealed tightly.
Inspect and remove any blockages.
2.Power unit does not
start, or shuts off during
normal operation with
no LED showing red or
illuminated.
Defective inlet. Check other wall inlets.
Thermoprotector has been activated OR there is
a tripped circuit breaker on the unit.
Blown fuse or tripped circuit breaker on house
electrical panel.
Defective hose.
Microprocessor lockup.
NOTE:This applies only to Broan VX6000C
and VX12000C.
Low line voltage.
Replace defective wall inlet.
Turn unit off for 20 minutes then plug unit back in.
If unit does not start, look for the tripped circuit
breaker behind the unit, a white button has
popped up, push it back to reset it. If circuit
breaker trips again, unplug your unit and contact
your local Service Center.
Replace fuse or reset circuit breaker on house
electrical panel.
Replace hose as required.
1) Push Reset button while unit is engaged OR
2) Unplug unit completely for 60 seconds.
Contact your local Service Center.
3.Power unit fails to stop
when the hose is
removed.
An electrical short has occurred somewhere in
the system.
A complete check of all wall inlets and power unit
low voltage control lead connections.
Contact your authorized Service Center.
4.Power unit shuts off
during normal operation,
lights on unit, wall valve
and hose are all red.
Debris pail full sensing has been activated. Empty debris pail as described in page 12.
5.On Broan VX6000C
and VX12000C units
only, all lights on control
panel flash when unit is
first plugged in.
Low line voltage. Contact your local Service Center.