MODEL QTRE100S
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3.Installationworkandelectricalwiringmustbedonebyaqualied
person(s) in accordance with all applicable codes and stan-
dards,includingre-ratedconstructioncodesandstandards.
4.Sufcientairisneededforpropercombustionandexhausting
of gases through the ue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
1.Forgeneralventilatinguseonly.Donotusetoexhausthazard-
ousorexplosivematerialsandvapors.
2.Thisproductisdesignedforinstallationinatceilingsonly.DO
NOTMOUNTTHISPRODUCTINAWALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4.Pleasereadspecicationlabelonproductforfurtherinformation
and requirements.
HUMIDITY SENSING FAN
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
Installer: Leave this manual with the homeowner.
Forquietandefcientoperation,longlife,andattractiveappear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motorbearingsaremakingexcessiveorunusualnoises,replace
the motor / blower wheel assembly.
SENSOR CLEANING
The humidity sensor is mounted in the control housing. The sensor
will operate most reliably when cleaned occasionally as follows:
1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth, clean toothbrush,
orlightly vacuum toclean sensor andgrille. DO NOTUSE
ABRASIVECLOTH,STEELWOOLPADS,ORSCOURING
POWDERS.
3.DONOTUSEcleaningsprays,solvents,orwateronornear
the sensor!
OPERATION
The humidity control and fan can be operated separately. Use a
1- or 2-function wall control. Do not use a dimmer switch to operate
the humidity control. See “Connect Wiring” for details.
SENSOR OPERATION
The humidity-sensing
fan uses a sophisticated humidity sensor
that responds to: (a) rapid to moderate increases in humidity or (b)
humidity above a set-point. The humidity sensor may occasionally
turnthefanONwhenenvironmentalconditionschange.
MANUAL ON WITH TIMED OFF
The humidity sensing fan has an additional operation feature. For
odoror vaporcontrol, thefan canbe energizedbycycling the
powerswitch.Oncethefanhasbeenenergizedinthismanner,it
will remain on for 20 minutes.
Tomanuallyenergizethefan:
1.IffanpowerswitchisalreadyON,proceedtoStep2;otherwise,
turnpowerswitchONformorethan1second.
2.TurnfanpowerswitchOFFforlessthan1second.
3.TurnfanpowerswitchbackONandfanwillturnON.
To register this product visit: www.broan.com
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - HUMIDITY SENSING FAN

Page 1MODEL QTRE100S WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in

Page 2 - INSTALL HOUSING &

Page 2MODEL QTRE100S TYPICAL INSTALLATIONSHousing mounted to I-joists.Housing mounted anywhere be-tween trusses using hanger bars.PLAN THE INSTALLA

Page 3 - CONNECT WIRING

Page 3MODEL QTRE100S 1b. Mount housing anywhere between trusses, joists, or I-joists using hanger bars. Sliding hanger bars are provided to allow

Page 4 - WARRANTY

Page 4MODEL QTRE100S SERVICE PARTS99044368A Key No. Part No. Description 1 97016466 Housing 2 97016449 Duct Connector - 4” 3 98010102 Wi

Page 5 - VENTILADOR CON SENSOR

Página 5MODELO QTRE100S ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENT

Page 6 - EL CONDUCTO

Página 6MODELO QTRE100S INSTALACIONES TÍPICASMontaje de la cubierta en viguetas “I”.Montaje de la cubierta en cualquier parte entre armaduras por

Page 7 - CONEXIÓN ELÉCTRICA

Página 7MODELO QTRE100S 1b. Instale la cubierta en cualquier parte entre las armaduras, viguetas o viguetas “I” por medio de barras de suspensión.

Page 8 - GARANTÍA

Página 8MODELO QTRE100S PIEZAS DE REPUESTO99044368A Clave n.º Pieza n.º Descripción 1 97016466 Cubierta 2 97016449 Conector de conductor, 1