Broan Elite 15SSEXF Service Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
30
Section D – Electrical Components
Remove two Phillips head screws and wire leads 3.
from the capacitor.
Discharge the capacitor (see Warning above).4.
Use an ohmmeter or multi-meter set on the “Ohms 5.
times 1000” scale (if available) to check resistance
across the wire terminals. The needle should jump
toward zero ohms and quickly move back to innity.
(NOTE: Some less-sophisticated meters will only tell
you if the capacitor is good or bad.)
If the needle does not move, if the needle reads a 6.
constant value or near zero ohms, or if the needle
jumps toward zero and then moves back to constant
high resistance (not innity), replace the capacitor.
Installation is the reverse of removal.7.
NOTE: On installation, route the wires through the notches
in the shield.