Page view 13
Make a water trap loop in the tube
to prevent the unit from drawing
unpleasant odors from the drain
source. Make sure this loop is located
BELOW the “T” as shown. This will
prevent water from being drawn
back up into the unit in case of
negative pressure. Run the tube to
the floor drain or to an alternative
drain pipe or pail. Be sure there is a
slight slope for the run-off.
14
5.6 INSTALLING THE EXTERIOR HOODS
Choose an appropriate location for installing the exterior hoods:
At a minimum distance of 6 feet (1.8 m) between the hoods to
avoid cross-contamination
At a minimum distance of 18 inches (457 mm) from the ground
Refer to figure 15 for connecting the insulated duct to the hoods.
Place the “FRESH AIR INTAKE” sticker, provided in the installation
kit, on corresponding hood. An “Anti-Gust Intake Hood” should be
installed in regions where a lot of snow is expected to fall.
CAUTION
All models require an exhaust hood with a backdraft damper. This damper closes when the unit is off and
prevents unwanted cold air from entering the house.
VD0028
EXHAUST
HOOD
OPTIONAL DUCT
LOCATION
TAPE AND DUCT TIE
CAULKING
INTAKE
HOOD
6ӯ
(152 MM)
18
(457 MM)
18
(457 MM)
6’
(1.8 M)
6’
(1.8 M)
18
(457 MM)
Figure 15
5.7 CONNECTING THE DRAIN
VO0005A
± 12"
305 mm)
± 12"
305 mm)
VO0003
1
2
VO0011
TO DRAIN
TIE-WRAP
3
5. Installation (cont’d)
Attach the 2 plastic drain fittings to
the unit using the gaskets, washers
and nuts as shown.
Cut 2 sections of plastic tubing,
about 12” (305 mm) long and attach
them to each drain fitting. Join the 2
short sections to the “T” junction and
main tube as shown.
VD0231A
± 1
If using a pail to collect water, locate the tube
end approximately 1” from the top of the pail in
order to prevent water from being drawn back
up into the unit.
WARNING
Make sure the intake hood is at least 6 feet (1.8 m) away
from any of the following:
Dryer exhaust, high efficiency furnace vent,
central vacuum vent
Gas meter exhaust, gas barbecue-grill
Any exhaust from a combustion source
Garbage bin and any other source of contamination
!