15
VT1W model
(U.S.A.)
6.1 MAIN CONTROLS
6. Control Devices
CONDENSATION CONTROL
AIR SUPPLY CONTROL
MIN.
MAX.
OFF
AIR
EXCHANGE
-20°C
-4° F
-5° C
23°F
5
°C
41°F
C
O
M
F
O
R
T
Z
O
N
E
S
U
M
M
E
R
VC0027
VT2W model
(U.S.A.)
-20°C
-4° F
-5° C
23°F
5
°C
41°F
CONDENSATION CONTROL
AIR SUPPLY CONTROL
CONDENSATION CONTROL
MAXIMUM SPEED
AIR EXCHANGE IN PROGRESS
MIN. MAX.
CONTINUOUS INTERMITTENT
20 MIN.
ON
40 MIN.
OFF
C
O
M
F
O
R
T
Z
O
N
E
S
U
M
M
E
R
VC0028
Dehumidistat
Designed primarily for use with our low price HRV (Heat Recovery
Ventilator) units, the dehumidistat helps control indoor maximum
humidity level during fall, winter and spring. This control should not
be installed in a house already equipped with other main controls
(except the 3-position switch). You will find a relative humidity %
scale instead of a temperature scale meant to reduce the window
condensation problems.
3-position switch
Some model may come with a 3-position mounted switch on the
electrical box on the exterior lower right front side. It is basically an
airflow control that gives the customer the choice between the low
and high speed or the OFF (REMOTE) position. This OFF
(REMOTE) position does not deactivate the optional controls.
CAUTION
All models require a main control.
Platinum model
(Canada)
VC0104
SMART
SET
MODE
PREF
U.S.A. MODELS DH100W VT1W VT2W
CANADIAN MODELS DEHUMIDISTAT
DECO-
T
OUCH
PLATINUM
MODES
OFF Position X X X X X
Intermittent exchange (TBI) 20 ON - 40 OFF X
Intermittent exchange OR OFF (ON - OFF or ON - Recirculation) X X
Low speed continuous exchange X X X X
High speed continuous exchange X X X X
SMART (entirely automatic mode optimizing ventilation) X
Program (programs the desired ventilation according to the period of the day) X
Recirculation (manual mode performing air recirculation inside the house) X X
DETECTOR
TYPES
Humidity control (Relative humidity scale %) X
Indoor condensation control (Temperature scale) X X
Outdoor temperature X
Indoor relative humidity X
INDICATORS
Mode indicator X X X X
Air exchange indicator X X X
Condensation/Polluant control max speed indicator X
Maintenance indicator X X X
Day and hour indicators X
SWITCHES
Sliding button X
Push button X X X
Deco-Touch model
(Canada)
VC0117