8. Wiring Diagrams (cont’d)
NOTES
1- Controls cannot be connected to J3.
2- The factory set wiring for blower speed selection is
high and low. Medium speed can be selected instead of
low speed. Disconnect the RED wire from the motor
RED tap and connect it to the motor BLUE tap.
3- If any of the original wire, as supplied, must be
replaced, use the same or equivalent wire.
4- Use the factory supplied protective tubing.
5 Field installed option: Use only factory supplied kit.
6- The field wiring must comply with applicable codes,
ordinances and regulations.
6- The furnace fan circuit must be class 2 circuit only.
7- SPECIFIED UL LISTED/CSA CERTIFIED LINE
FUSE. LittelFuse (225 003), 2AG Fast-Acting
Fuse, 224/225 Series. Rating: 3 A
FUNCTION TABLE
RELAY
MODE K1 K2 K5
Intermitent
0
0
0
Exchange Low 1 0 1
Exchange High
1
1
1
Circulation Low 1 0 0
Circulation High
1 1 0
Defrost Cycle 1 1 0
OFF
0 0 0
0 = Relay coil is de-energized
1 = Relay coil is energized
JUMPERS
TABLE
MODELS
TYPES
DEFROST TIME
DEFROST/VENTILATION
MINUTES
JU1A
JU1B
JU1C
JU1D JU1E JU1F JU1G
23°F
-5°C
5°F
-15°C
-17°F
-27°C
OUT OUT
OUT
OUT OUT IN IN
HRV100H
HRV200H
6/32 6/32 6/20
OUT OUT
OUT OUT OUT OUT IN
EXTENDED
DEFROST
ALL TYPES
10/30 10/20
10/15
JU1
• •
•
• •
•
•
•
•
• • • •
•
A B
C
D
E F
G
2
1
Models: HRV100H, HRV200H
Connection
Logic
Risk of electric shocks. Before performing any maintenance or servicing, always disconnect the unit from its power
source. This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation.
If the fuse blows, unplug the product from the outlet. Replace the fuse as per the servicing instructions (follow
product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short-circuit may be
present and the product should be discarded or returned to an authorized service facility for examination and/or repair.